Assessment

VERITAS is one of the leading, safety assessment firm in Bangladesh, working in those services relate to design, safety, compliance and improvement of Quality Health Safety, Environment, Social Accountability and including conformity assessment services.

GET IN TOUCH

To know more, please fill the
form below…

Assessment
  • Detail Engineering Assessment (DEA)
  • Detail Engineering Assessment (DEA) process as per Alliance standard: Essential Information and steps for Detail Engineering Assessment (DEA)
DEA Steps:
  • Prepare As-built Architectural +Structural drawing, if not available already. The as-built drawing shall show:
  • The structural, nonstructural elements with dimensions at all levels, foundations and framing on plan, section and elevation.
  • Cross-sectional drawings showing reinforcements in foundations, columns, beams, slabs etc.
  • If as-built drawings are available–verify if it truly represents the structure.
  • As-built drawing shall be prepared/checked as per Alliance standard 8.19 and/or 8.20.
  • Scanning of rebar’s in main structural elements of lower tiers (SeeAPD.5) to confirm as-built condition.
  • Arrange confirmatory soil test(2/3borings)
  • Spot check of foundation by excavation, if necessary
  • Identify causes of any physical distress, dampness or any other abnormalities and suggest remedial measures.
  • Work on specific terms of concern identified by the QAF in the initial structural assessment report
  • Identify any overloading, additions, extensions, presence of water tanks, towers. Study their effect on the structure and suggest remedial measures.
  • Arrange for core test by taking 4 Nos. 4in. cores (see details in APD.5, D.17) to assess in situ strength. Use ACI 562 to find 𝒇′𝒆𝒒 to be used in design checking.
  • Prepare structural model as per As-built drawing using appropriate software by following the standard practice and building code.
  • Obtain reliable data on steel grade or arrange testing of steel rebar (if possible) or assume 40grade conservatively for using in all analysis/design adequacies.
  • Use loading and Load factors as per standard (NTC/Alliance)
  • Check strength and serviceability requirements as per BNBC-2006
  • Make recommendation(s) based on results of DEA–including restriction of loading, restriction on vertical extension.
  • In case of deficiency in structural integrity of the structure(s), appropriate retrofitting scheme is to be designed.
  • Prepare Load Plan and arrange posting of load plan and approve it.

 

DEA Deliverables:
  • Approved As-built structural architectural drawings.
  • DEA Report with following items:
  • Highlight any variation between as built and designed structure (if known)
  • Results of testing for strength and materials
  • Results of geotechnical investigation
  • Details of loading, inputs and results of computer modeling
  • Commentary on adequacy/inadequacy of elements of the structure
  • Schedule of any required retrofitting required for safety or safe performance of structure
  • If applicable, retrofitting scheme design with detail working drawings and design assumptions/notes Approved Load plans.